Specifications
ASMi-52 Installation and Operation Manual  Chapter 1 Introduction 
  Technical Specifications  1-9 
Control Port 
Type 
DTE/DCE 
Format 
8 bits, no parity 
Baud Rate 
9.6, 19.2, 38.4, 57.6, 115.2 kbps 
Connector 
9-pin, D-type female 
Interface 
10/100BaseT 
Ethernet 
Control Port 
Protocol 
MAC 
Connector 
RJ-45 
Timing 
Derived from three alternative sources: 
•  Internal oscillator 
•  External, from the attached DTE 
•  Receive, derived from the received signal 
Diagnostics 
Loopbacks 
ITU V.54: 
•  Local loopback, activated via management software or by 
the DTE interface signal (V.35 and RS-530 only) 
•  Remote loopback, activated via management software or 
by the DTE interface signal (V.35 and RS-530 only) 
•  Remote loopback at SHDSL repeater 
Statistics Collection 
•  E1 with CRC-4 or T1 with ESF framing: per ITU G.706 
•  E1 without CRC-4 or T1 with SF framing: bipolar 
violations (BPV) 
•  SHDSL performance 
Alarm Relay 
Operation 
Normally Open and Normally Closed, using different pins 
Connector 
Terminal block, 6-pin 
Indicators 
PWR (green) 
Power 
TEST (red) 
Test 
SYNC A/B 
(green/red) 
Synchronization of DSL line 
DATA (yellow) 
Data Transfer (except E1 and T1 options) 
E1/T1 SYNC (red) 
Loss of E1/T1 synchronization (E1 and T1 options only) 
AIS (yellow) 
“All 1s string” is received at the E1 interface 
(E1 option only) 
YELLOW (yellow) 
“All 1s string” is received at the T1 interface 
(T1 option only) 
ALM (red) 
Alarm 