Specifications

Chapter 4 Managing ASMi-52 via a Terminal ASMi-52 Installation and Operation Manual
4-38 Displaying the ASMi-52 Status
Displaying the System Status
To display the system information:
1. Display the system status menu. (Path: Monitoring >System monitoring >
System local/remote status)
2. Select System local status to display the local device status information or
select System remote status to display the remote device status information.
The System Status screen appears (see Figure 4-41).
ASMi-52
System Status
Device Type (ASMi-52_M (PLASTIC) - STU_C-2W)
Clock Source (INT)
Software Version (1.00E54)
Hardware Version (0.00)
FPGA Version (0.05)
Hardware Status (NO HARDWARE FAILURE)
PS (WIDE RANGE)
MAC address (0 00 10 40 00 0)
IP address (1.1.1.1)
Alarm Indication (MAJOR)
Test Indication (OFF)
>
ESC-prev.menu; !-main menu; &-exit;
Figure 4-41. System Status Screen
Alarms are described in Chapter 5.
Displaying the Port Status
To display the port status information:
1. Display the Physical Port Status menu. (Path: Monitoring menu > Physical Port
Monitoring > Physical Port Status)
2. From the Physical Port Status menu select:
Physical Port Local Status to display the local port status information
Physical Port Remote Status to display the remote port status information
Physical Port Repeater Status to display repeater alarms (see Chapter 5 for a
detailed description).
The Physical Port Local/Remote Status menu appears.
3. From the Physical Port Local/Remote Status menu, select Port Local/Remote
Status to display the port status.
The Port Status screen appears (see Figure 4-42).
Note