Chapter 5 Configuring a Typical Application ASMi-52 Installation and Operation Manual
5-2 Configuring the ASMi-52 units
5.2 Configuring the ASMi-52 units
Two ASMi-52 units must be configured for this application. Both units have the
same configuration parameters, except for the host IP address and the master clock
mode.
To prepare a control session:
1. Connect the terminal cable to the CONTROL connector of ASMi-52.
2. Turn the control terminal on.
3. Configure the terminal to the default communication parameters: 9.6 kbps,
one start bit, eight data bits, no parity, one stop bit, VT100 emulation.
4. Select the full duplex mode.
5. Turn the terminal echo off.
6. Disable any type of flow control.
You are now ready to start a control session.
To enter the user name and password:
1. Type in your user name and press <Tab>.
You can leave the user name field empty (default), the default password is 1234.
2. Type in your password at the > prompt (up to eight characters).
ASMi-52 responds to your entry with asterisks.
3. Press <Enter>.
The Main menu is displayed.
Setting the ASMi-52 System
To configure the master clock.
1. Display the Master Clock menu (Main menu > Configuration > System
configuration > Master Clock)
The Master Clock menu appears.
ASMi-52
Master clock (Internal)
Receive
Internal
External
>
ESC-prev.menu; !-main menu; &-exit; @-scroll
2. From the Master Clock menu, three clock modes are given Receive, Internal,
or External.
Set the CO ASMi-52 unit clock to Internal
Set the CPE ASMi-52 unit clock to Receive
Note