6-8 Error Detection   
Table 6-1. ASMi-52 Alarms and Warnings (Cont.) 
Number Terminal Message  Port  Description  Severity 
42 WIRE MODE NOT 
COMP 
SHDSL  Mismatch between line interface types (2/4-wire) 
between local and remote units 
Major 
43  SPAN IS NOT FULL  SHDSL  Distance between adjacent repeaters is too long. 
You can identify the problematic segment by 
checking the Port Status screen. In the Number of 
Repeaters line, it displays the last repeater 
identified by ASMi-52. This means that the 
distance between the last detected repeater and 
the next repeater exceeds it maximum range. 
Major 
44 LOOP ATTN. OVER 
NETWORK SIDE 
SHDSL  Loop attenuation at the network side of the 
repeater has exceeded the alarm threshold 
Minor 
45 LOOP ATTN. OVER 
CUSTOMER SIDE 
SHDSL  Loop attenuation at the customer side of the 
repeater has exceeded the alarm threshold 
Minor 
46  SNR MARGIN OVER 
NETWORK SIDE 
SHDSL  Signal-to-noise margin at the network side of the 
repeater has exceeded the alarm threshold 
Minor 
47  SNR MARGIN OVER 
CUSTOMER SIDE 
SHDSL  Signal-to-noise margin at the customer side of the 
repeater has exceeded the alarm threshold 
Minor 
48  LOSW FAILURE OVER 
NETWORK SIDE 
SHDSL  Loss of Sync Word is detected at the network 
side of the repeater 
Minor 
49  LOSW FAILURE OVER 
CUSTOMER SIDE 
SHDSL  Loss of Sync Word is detected at the customer 
side of the repeater 
Minor 
50  LINE PARAMERS NOT 
COMP 
SHDSL  Modems fail to synchronize due to the 
configuration parameters mismatch. For example: 
•  The modems operate in the adaptive mode 
(Line Prob is set to Adaptive Rate) and 
distance between them exceeds the 
maximum range. 
•  ASMi-52 with V.35 interface operates 
opposite remote unit with E1 interface. If the 
modem V.35 is set to the data rate which is 
not supported by the remote unit, e.g. 
2304 kbps, the units will not synchronize. 
Major 
51 EXTERNAL TO 
INTERNAL CLOCK 
DTE  Device is in External clock, but clock is not 
connected 
Major 
Table 6-2. ASMi-52 Events 
Terminal Message  Description 
CRC EVENT LINE A  CRC errors are detected on line A 
CRC EVENT LINE B  CRC errors are detected on line B 
SW DOWNLOAD FAIL  Software download failed 
BUFFER OVERFLOW  More than 100 entries registered in the log file 
WD RESET FROM GS  Watchdog error from the SHDSL chipset 