User`s manual
Chapter 3 Port Management  RADview FCD-IP User’s Manual 
3-28  Configuring Physical Parameters   
Table 3-17. Voice Parameters (Cont.) 
Parameter  Possible Values / Remarks 
Tx Ring Detection  This object represents 2 Octets, 4 nibbles: 
A bit
, A bit Inverted, B bit, B bit inverted, NA (FXS and E&M) 
where: 
0001=Tx A bit 
0010=Tx A bit inverse 
0011=Tx B bit 
0100=Tx B bit inverse 
0000=NA 
Default ABCD Bits  For all interfaces: 
When A bit or A bit inverted: 
For E1 Link: 
0001
, 0010, 0011, 0100, 0101, 0110, 0111 
For T1 Link: 
0000
, 0101 
Else, 
For E1 Link: 
0001
, 0010, 0011, 1000, 1001, 1010, 1011 
For T1 Link: 
0000
, 1010 
Reversed Polarity  Indicates the Signaling Profile of the port.  
Enabled, Disabled
Seize Ack  Indicates whether the device will acknowledge a seize signal (On/Off Hook). 
When the value is Yes and device receives an on/off hook signal, it will transmit 
back an on/off hook signal. 
When the value is set to No and device receives an on/off hook signal, it will NOT 
transmit back an on/off hook signal. 
Yes, No, NA (FXS and E&M) 
Out of Service 
Forced Idle, Forced Busy, NA (FXS) 
Remote E&M Wires  Remote device’s wiring. 
2 Wires, 4 Wires, NA (FXS and FXO) 
E&M Type  Indicates signaling type on the E&M analog side. 
Type 1, Type 2, Type 3, Type 5 (SSDC5), NA (FXS and FXO) 