User`s manual
Chapter 3 Port Management  RADview FCD-IP User’s Manual 
3-38  Performing Diagnostic Tests   
3.7  Performing Diagnostic Tests 
RADview enables you to run diagnostic tests for: E1/T1 Link, E1/T1 Sublink, 
SHDSL, SUB1/ LINK2, SUB 2, SUB 3, Voice Port. 
When configuring TDM (Voice) parameters a password is required. 
 
 To run diagnostics tests: 
1.  Select a Link or Channel. 
2. Select Diagnostics > Test… 
The Testing dialog box appears. 
Figure 3-28. Testing 
Table 3-26. Testing Parameters 
Parameter  Possible Values / Remarks 
Port  The selected port. 
Voice 1, Voice 2, Voice 3, Voice 4 
Interface Type  The interface type of selected port. 
FXS, FX0, E&M 4 W, E&M 2W 
Current Test  The currently running test. 
New Test 
Remote Digital Loopback (T1 only), Remote Analog Loopback, Local Analog 
Loopback 
[Stop Test]  Click <Stop Test> to stop a currently running test. 
[Set]  To run a different test, ensure that no test is currently running (click Stop Test). Select 
the test to be run from the New Test list box and click <Set>. 
 
To run a different test: 
1. Click <Stop Test> to stop any currently running test. 
2.  Select a new diagnostic test. 
3. Click <Set>. 
Note 