Specifications
Installation and Operation Manual  Chapter  6 Troubleshooting and Diagnostics 
FCD-E1LC Ver. 1.0  Handling Alarms  6-9 
Table 
6-2. FCD-E1LC Alarm Messages (Cont.) 
Alarm 
Number 
Terminal Message  Description  Corrective Actions  Severity  Type 
30 
BPV ERROR 
Bipolar violations in the main link 
receive signal. Updated once per 
second 
Have the main link checked. Perform the power-up self-test 
and replace the FCD-E1LC if a failure is detected 
MINOR ON 
31 
EXCESSIVE ERR 
RATIO 
The bit error rate of the link receive 
signal exceeds 1 × 10
-3
1.  Problem in the network facilities used by the main link. 
2.  Turn the FCD-E1LC off for a few minutes, and then 
turn it back on and read the alarm messages generated 
during the power-up self-test. Replace the FCD-E1LC if 
a failure is detected 
MAJOR ON/OFF 
32 
CRC-4 ERROR 
CRC-4 errors detected in the main link 
receive signal. Updated once per 
second 
1.  Have the link checked. 
2.  Perform the power-up self-test and replace the 
FCD-E1LC if a failure is detected 
MINOR ON 
34 
SFIFO SLIP 
Technical problem (FIFO 
overflow/underflow), usually caused by 
differences in clock rates 
1.  Check the clock mode of the corresponding data channel. 
2.  Turn the FCD-E1LC off for a few minutes, and then 
turn it back on and read the alarm messages generated 
during the power-up self-test. Replace the FCD-E1LC if 
a failure is detected. 
MAJOR ON 
35 
LOOP INBAND ON 
An inband activated loopback is now 
connected on the data channel 
If the loopback is no longer needed, disconnect it  MAJOR  ON 
36 
MANAGEMENT PORT IS 
LOOPED 
The management port receives its own 
messages (this could be caused by a 
test loopback on the communication 
path used for SNMP management or on 
the management port). Management is 
not possible while this condition is 
present 
Find the location of the loopback and request 
disconnection 
MAJOR ON/OFF 