Alarm 
Number 
Terminal Message  Description  Corrective Actions  Severity  Type 
37 
MANAGEMENT PORT IS 
DOWN 
The FCD-E1LC cannot communicate 
with the network management 
station. This may indicate incorrect 
setup of the management port 
parameters, a problem on the 
communication path, or a hardware 
failure 
1.  Correct the parameters. 
2.  Check for disconnection. 
3.  Check for hardware failure. 
4.  Check the management communication path 
MAJOR ON/OFF 
38 
DUPLICATE NAME IN 
THE NETWORK 
Another node in the network uses the 
FCD-E1LC logical name. This prevents 
SNMP management 
Check and change as required  MAJOR  ON/OFF 
42 
LINK INTEGRITY 
ERROR 
The Ethernet interface is not 
connected to an operating LAN 
Check the cable connecting the LAN, the LAN media, and 
check that at least one station is active on the LAN 
MAJOR ON/OFF 
43 
RTS/CONTROL IS OFF 
Indicates that the RTS signal on the 
DTE unit is off. 
Set the RTS signal on the DTE unit to ON state.  MAJOR  ON/OFF 
60 
CRC MF ALARM 
Local loss of synchronization to the 
CRC-4 multiframe on the main link 
(only on E1 port operating with CRC-4 
enabled) 
1.  Check cable connections to the port connector. 
2.  Check line and/or other communication equipment 
providing the link to the remote unit.  
3.  Replace the FCD-E1LC unit. 
MINOR ON 