Specifications
Chapter  6 Troubleshooting and Diagnostics  Installation and Operation Manual 
6-24  Testing the Unit  FCD-E1LC Ver. 1.0 
This test checks end-to-end the data link, including the cables connecting the 
remote user’s equipment to the FCD-E1LC, the remote FCD-E1LC, the 
transmission plant connecting the two FCD-E1LC, and the local FCD-E1LC (except 
for the data channel interface). 
User's
Equipment
Local FCD-E1LC
Data
Channel
Main
Link
Remote FCD-E1LC
Sub Link
Main
Link
Data
Channel
User's
Equipment
Sub
Link
User's
Equipment
User's
Equipment
Transmission
Plant
Processor Processor
Figure 
6-11. Data Channel Remote Loopback 
Allowed Loopback Combinations 
Not all of the loopback combinations are allowed, because some loopbacks 
disconnect the signal paths of other loopbacks. If you try to activate an illegal 
loop combination, FCD-E1LC sends a configuration error (ERROR 051: ILLEGAL 
PORT LOOP COMBINATION). 
For example: 
•  It is not possible to activate simultaneously remote (including 
inband-activated) and local analog loopbacks on the main link because that 
would disconnect the signal source for the local loopback. 
•  It is not possible to activate any remote data channel or sublink loopback 
when any main link loopback (analog or digital, local, remote or 
inband-activated) is activated 
•  It is not possible to simultaneously activate local and remote loopbacks on 
the same data channel. 
The following types of loopbacks can however be simultaneously activated: 
•  Main link: remote analog loopback and local digital loopback, and 
inband-loopback activation together with BER testing 
•  Sublink: remote digital loopback and local analog loopback 
•  You can simultaneously activate loopbacks of any type on different data 
channels, or a data channel and the sublink. 
To help you decide when you are not sure whether you can activate an additional 
loopback while one is already activated, you can find in the following tables 
(
Table 
 6-5 to 
Table 
 6-12) systematic lists of allowed (Yes) and not allowed (No) 
loopbacks for each combination of ports. Active indicates the already activated 
loopback. 
It is not possible to activate loopbacks on the Ethernet port. You can only 
activate inband loopbacks and test the BER in the main link timeslots assigned to 
the Ethernet port, to check transmission quality for the Ethernet payload. 
Note 