Specifications
Installation and Operation Manual  Appendix  A Connection Data 
FCD-E1LC Ver. 1.0  Data Channel Connection Data  A-5 
Table A-3. Data Channel Connector, Pin Assignment 
Pin Direction  Designation  Function  RS-530 Circuit 
1 
↔ 
FG Frame Ground  AA 
2  Input  SDA  Send Data (wire A)  BA(A) 
3  Output  RDA  Receive Data (wire A)  BB(A) 
4  Input  RTSA  RTS (wire A)  CA(A) 
5  Output  CTSA  CTS (wire A)  CB(A) 
6  Output  DSRA  DSR (wire A)  CC(A) 
7 
↔ 
SG Signal Ground  AB 
8  Output  DCDA  DCD (wire A)  CF(A) 
9  Output  RCB  Receive Clock (wire B)  DD(B) 
10  Output  DCDB  DCD (wire B)  CF(B) 
11  Input  SCEB  External Send Clock (wire B)  DA(B) 
12  Output  SCB  Send Clock (wire B)  DB(B) 
13  Output  CTSB  CTS (wire B)  CB(B) 
14  Input  SDB  Send Data (wire B)  BA(B) 
15  Output  SCA  Send Clock (wire A)  DB(A) 
16  Output  RDB  Receive Data (wire B)  BB(B) 
17  Output  RCA  Receive Clock (wire A)  DD(A) 
18  Input  LLBA  Local Loopback Activation (wire A)  – 
19  Input  RTSB  RTS (wire B)  CA(B) 
20  Input  DTRA/RCEA  DTRA/External Receive Clock (wire A)  CD(A) 
21  Input  RLBA  Remote Loopback Activation (wire A)  – 
22  Output  DSRB  DSR (wire B)  CC(B) 
23 Input  DTRB/RCEB  DTRB/External Receive Clock (wire B)  CD(B) 
24  Input  SCEA  External Send Clock (wire A)  DA(A) 
25  Output  TMA  Test Mode Indication (wire A)  – 
Connection Data for Data Channel with RS-530 Interface 
The functions of the pins in the RS-530 data channel interface connector are 
listed in 
Table A-3
. The following sections provide information on the cables 
required to connect user’s equipment to a data channel with RS-530 interface in 
the various timing modes. 
DCE Mode 
This mode is used to connect to user’s equipment with DTE interface. The user’s 
equipment can be directly connected to the FCD-E1LC channel connector using a 
standard “straight” RS-530 cable (i.e., a cable wired point-to-point). The 
“straight” cable is terminated in a 25-pin male D-type connector at the FCD-E1LC 
side. 