Specifications
Appendix  A Connection Data  Installation and Operation Manual 
A-6  Data Channel Connection Data  FCD-E1LC Ver. 1.0 
DTE1 Mode 
This mode is used to connect to user’s equipment with DCE interface that can 
accept, as its external clock, the receive clock signal provided by the FCD-E1LC 
data channel. 
In this case, it is necessary to connect a 25-pin male/25-pin male cross-cable (see 
Figure A-5
) wired in accordance with 
Table A-4
, between the FCD-E1LC CHANNEL 
connector and the user’s equipment RS-530 connector. 
Figure A-5. RS-530 Adapter Cable for DTE1 Mode 
Table A-4. Wiring of RS-530 Adapter Cable for DTE1 Mode 
FCD-E1LC Side  Designation  Function  User’s Side 
1 FG Frame Ground  1 
2  SDA  Send Data (wire A)  3 
3  RDA  Receive Data (wire A)  2 
4  RTSA  RTS (wire A)  8 
5  CTSA  CTS (wire A)  – 
6  DSRA  DSR (wire A)  20 
7 SG Signal Ground  7 
8  DCDA  DCD (wire A)  4 
9  RCB  Receive Clock (wire B)  11 
10  DCDB  DCD (wire B)  19 
11  SCEB  External Send Clock (wire B)  9 
12  SCB  Send Clock (wire B)  – 
13  CTSB  CTS (wire B)  – 
14  SDB  Send Data (wire B)  16 
15  SCA  Send Clock (wire A)  – 
16  RDB  Receive Data (wire B)  14 
17  RCA  Receive Clock (wire A)  24 
18 – Not connected  – 
19  RTSB  RTS (wire B)  10 
20  RCEA  External Receive Clock (wire A)  – 
21 – Not connected  – 
22  DSRB  DSR (wire B)  23 