Specifications
Installation and Operation Manual  Appendix  D Supervision Terminal Commands 
FCD-E1LC Ver. 1.0  Commands D-29 
Syntax 
DEF SL 
Use 
1.  To define the sublink parameters, type: 
DEF SL<Enter> 
You will see the first row of the sublink parameters data form. A typical 
display is shown below: 
FRAME CRC-4 SYNC RX_GAIN IDLE_TS_CODE 
RAI 
G732N NO CCITT SHORT 3F 
DISABLE 
2.  Select the parameters in accordance with 
Table D-8
, and then press <Enter> 
to display the second row of the sublink parameters data form. 
You will see the second row of the sublink parameters data form. A 
typical display is shown below: 
CGA OOS_SIG OOS_CODE 
NONE N/A 00 
3.  Change the desired parameters and then press <Enter>: 
  If the FRAME parameter is UNFRM, the command is ended 
  If the FRAME parameter is G732N or G732S, you will see the timeslot 
mapping parameters row. A typical form is shown below. 
MAP_MODE START_TS TS_TYPE NUM_OF_TS 
USER N/A N/A N/A 
4.  Select the MAP_MODE and then press <Enter>. 
Before continuing, refer to the Sublink Timeslot Mapping Considerations
section 
below for mapping guidelines. 
5.  If in Step 4 the MAP_MODE has been set to SEQ: 
  Press the spacebar to move to the START_TS field, and then press <F> or 
<B> to select the desired starting timeslot. 
  Press the spacebar to move to the TS_TYPE field, and then press <F> or 
<B> to select the desired timeslot type.  
  Press the spacebar to move to the NUM_OF_TS field, and then press <F> 
or <B> to select the required number of timeslots. Note that if you select 
00
, no sub timeslot is connected to the main link. 
  Press <Enter>. The command is ended and the FCD-E1LC will display the 
time and date, followed by the FCD-E1LC prompt. 
Note 