Specifications
Appendix  D Supervision Terminal Commands  Installation and Operation Manual 
D-36 Commands  FCD-E1LC Ver. 1.0 
DEF SYS 
Purpose 
Define the system parameters. Refer to 
Table D-10
 for the parameter 
description, allowable ranges and configuration guidelines. 
Syntax 
DEF SYS 
Use 
To define the FCD-E1LC system parameters, type: 
DEF SYS<Enter> 
The system parameters data form is displayed. A typical form is shown 
below. The form presents the current parameter values as defaults. 
CLK_MASTER CLK_FBACK DATE_FORMAT 
ML NONE DD-MM-YYYY 
After the desired parameter values are selected, press <Enter> to end. 
Table D-10. System Configuration Parameters 
Designation Function  Values  Configuration Guidelines 
CLK_MASTER 
Selects the master 
system timing 
reference. 
INT – Internal oscillator. 
ML – Locked to the recovered main 
link receive clock. 
SL – Locked to the recovered sublink 
receive clock. 
CH1 – Locked to the external clock 
supplied to the user data channel 1, 
provided the channel timing mode is 
DTE2. 
CH2 – Locked to the external clock 
supplied to the user data channel 2, 
provided the channel timing mode is 
DTE2. 
Default: ML 
Select ML for connection to 
carrier lines. 
Select CH1 or CH2 for 
connection to a data 
network. 
Select INT at one end and 
ML at the other end for 
point-to-point lines. 
CLK_FBACK 
Selects the alternate 
(fallback) system 
timing reference, for 
use in case the 
master reference 
fails. 
NONE – No fallback source is used. In 
this case, the internal oscillator is 
automatically selected when the 
master reference fails. 
ML – Locked to the recovered main 
link receive clock. 
SL – Locked to the recovered sublink 
receive clock. 
Select a source different 
from that selected as 
master. 
Select NONE to disable 
switching to the fallback 
source. In this case, the 
default fallback clock source 
is the FCD-E1LC internal 