Specifications
Appendix  D Supervision Terminal Commands  Installation and Operation Manual 
D-40 Commands  FCD-E1LC Ver. 1.0 
use the following command to display the results and start the injection of 
errors: 
DSP BERT ML /I<Enter> 
and the command 
DSP BERT ML /S<Enter> 
to display the results and then stop the injection of errors. 
The BER test results displayed on the screen are correct for the instant the 
display command has been issued (or since the last time the counters have been 
cleared, whichever occurred last). When the /R option is used, the results are 
periodically updated. The results are presented in the following format: 
BERT OF CHANNEL - 1 
ERROR_BITS RUN_TIME(SEC) ERRORS(SEC) SYNC_LOSS(SEC) 
ERROR_INJECT 
0 3 0 0 OFF 
The display fields are as follows: 
ERROR_BITS  Total number of bit errors detected. 
RUN_TIME(SEC)  Total time the test is running. 
ERRORS(SEC)  Total number of seconds in which errors have been 
detected. 
SYNC LOSS(SEC)  Total number of seconds in which loss of frame alignment 
occurred. 
ERROR INJECT(SEC)  Indicates whether errors are injected (ON) or not (OFF). 
All the counters have a range of 0 through 65535. When the maximum value is 
reached, the counter freezes, therefore in general a value of 65535 indicates the 
counter has overflown. 
DSP HDR TST 
Purpose 
Display the results of the last hardware test (made during power-on self-test and 
during regular operation). 
Syntax 
DSP HDR TST 
Note 