Specifications
Chapter  1 Introduction  Installation and Operation Manual 
1-2  Typical Applications  FCD-E1LC Ver. 1.0 
  10/100BaseT Ethernet bridge with VLAN support, for direct connection to 
LANs. 
Both optional ports can be added to the same FCD-E1LC unit. 
In this manual, the generic term FCD-E1LC is used when the information is 
applicable to all the FCD-E1LC versions. Information applicable to a specific 
version is explicitly identified. 
Main Features 
The FCD-E1LC main and sublink interfaces are compatible with virtually all 
carrier-provided E1 services, meeting all the applicable requirements of 
ITU-T Rec. G.823, G.703, G.704, G.706 and G.732. The interfaces support either 
2 or 16 frames per multiframe, with or without CRC-4. Line code is HDB3. 
Timeslot assignment is programmable, allowing data from each user port to be 
placed into user-selectable timeslots. 
FCD-E1LC supports various timing modes, to meet the specific requirements of 
user’s applications and enable hierarchical dissemination of timing within the 
network. Its nodal timing can be locked to: 
•  The clock signal recovered from the main link 
•  The optional sublink 
•  The receive clock of a serial data channel. 
Alternatively, an internal oscillator can provide the timing. 
FCD-E1LC operation can be controlled and monitored by means of supervision 
terminals, Telnet hosts, and SNMP management stations. The management 
communication can be either out-of-band, e.g., via connections to the FCD-E1LC 
serial management port (either directly or through modem links), or inband with 
the management traffic carried by the main link. These capabilities ensure that 
FCD-E1LC units can be fully managed from one or more remote locations, in 
accordance with the specific requirements of the using organization. 
FCD-E1LC has a universal power supply that can operate on a wide range of AC 
and DC power sources, including 100 to 240 VAC, 50/60 Hz and -48/-60 VDC, and 
has low power consumption.  
The FCD-E1LC is available as a standalone unit, intended for installation on 
desktops or walls. An optional rack mount adapter kit enables installing one or 
two FCD-E1LC units in a 19-inch rack, occupying only 1U. 
Note 










