Specifications
Installation and Operation Manual  Chapter  4 Configuration 
FCD-E1LC Ver. 1.0  FCD-E1LC Command Language  4-5 
Configure the FCD-E1LC Control Port for Telnet and SNMP 
Access 
To use the FCD-E1LC control port for Telnet and SNMP access, use the DEF SP 
commands, as applicable, and select the following parameters: 
•  Select the appropriate data rate in the SPEED field. Do not select AUTO. 
•  Select NMS SLIP or NMS PPP in the AUXILIARY DEVICE field.  
When using SLIP, if the FCD-E1LC control port is connected to a serial port of 
another RAD equipment unit, for example, a Megaplex-2100/2104, make sure to 
select 
SLIP AGENT
 in the 
AUXILIARY DEVICE 
field. 
At this stage, you can start using Telnet hosts or SNMP management stations to 
perform FCD-E1LC configuration activities. 
Ending the Control Session 
Type EXIT to end a supervision terminal session. 
Type BYE to end a Telnet session. 
4.2  FCD-E1LC Command Language 
This section presents the FCD-E1LC command language, its syntax and command 
options, and an index of the supported commands. 
Command Syntax 
This section presents the supervision language syntax. 
Enter commands at the FCD> prompt. This prompt appears at the beginning of 
each new line. The cursor appears to the right of the prompt. 
If a node number is required, enter the node number before the command using 
the following syntax: 
NODE<SP>‘node number’<SP>‘command’<Enter>. 
FCD-E1LC echoes commands as you enter them, character by character. 
Use <Space> as a separator between command fields and/or parameters. 
To correct typing errors, press <Backspace> until the error is cleared, then enter 
the correct characters. 
To execute a command, press <Enter>. After when the command is executed, 
FCD-E1LC displays the current date and time, and then displays a new command 
prompt. 
After the last page of the data form, press <Enter> to initiate command 
evaluation. 
Note 










