Specifications
Chapter  5 Configuring FCD-E1LC for a Typical Application  Installation and Operation Manual 
5-6  Configuration Example  FCD-E1LC Ver. 1.0 
MULTIPLIER SPEED FIFO_SIZE CLOCK MODE CTS CLOCK_POLARITY 
64 128 AUTO DCE ON NORMAL 
MAP_MODE START_TS TS_TYPE 
SEQ 1 DATA 
TS : 1 2 3 4 5 6 7 8 
TYPE : DATA DATA NO NO NO NO NO NO 
TS : 9 10 11 12 13 14 15 16 
TYPE : NO NO NO NO NO NO NO NO 
TS : 17 18 19 20 21 22 23 24 
TYPE : NO NO NO NO NO NO NO NO 
TS : 25 26 27 28 29 30 31 
TYPE : NO NO NO NO NO DEDIC NO 
Check Main Link Timeslot Assignment 
Type DSP TS to check main link timeslot assignment. 
The resulting display is shown: 
TS : 01 02 03 04 05 06 07 08 09 10  
TYPE : DATA DATA NC NC NC NC VOICE VOICE VOICE VOICE  
DEST :  CH1  CH1  NA  NA  NA  NA  SUB  SUB  SUB  SUB   
TS : 11 12 13 14 15 16 17 18 19 20  
TYPE :  VOICE VOICE VOICE VOICE VOICE DATA  VOICE NC  NC  NC   
DEST :  SUB  SUB  SUB  SUB  SUB  SUB  SUB  NA  NA  NA   
TS : 21 22 23 24 25 26 27 28 29 30 31 
TYPE : NC NC NC NC NC NC NC NC NC NC NC 
DEST : NA NA NA NA NA NA NA NA NA DEDIC NA 
Configure System Timing 
Type DEF SYS to configure the FCD-E1LC nodal timing: 
  Lock FCD-E1LC timing to the recovered main link clock 
  Use the internal oscillator as fallback source. 
After configuration, you should see the following display: 
CLK_MASTER CLK_FBACK DATE_FORMAT 
ML NONE DD-MM-YYYY 
Configuring the Remote FCD-E1LC 
Repeat the procedure for the other FCD-E1LC. 