Installation and Operation Manual  Chapter  6 Troubleshooting and Diagnostics 
FCD-E1LC Ver. 1.0  Handling Alarms  6-7 
Table 
6-2. FCD-E1LC Alarm Messages (Cont.) 
Alarm 
Number 
Terminal Message  Description  Corrective Actions  Severity  Type 
11 
DATABASE CHECKSUM 
ERROR 
FCD-E1LC technical failure (the 
database currently stored in the 
non-volatile memory of FCD-E1LC is 
corrupted) 
1.  Use the supervision terminal to enter the INIT DB 
command. 
2.  Turn the FCD-E1LC off for a few minutes, and then 
turn it back on and read the alarm messages 
generated during the power-up self-test. Replace the 
FCD-E1LC if a failure is detected 
MAJOR ON/OFF 
12 
PSWRD SWITCH IS ON 
PWD section of switch SW2 is set to 
ON 
If it is no longer necessary to enforce the default password 
and node number, return the switch section to OFF 
MINOR ON 
13 
SP-PAR SWITCH IS 
ON 
Section DEF PAR of switch SW2 is set 
to ON 
If this setting is no longer required, return the switch 
section to OFF. 
MINOR ON 
15 
DIAL-OUT PRIMARY 
CALL FAILED 
The call attempts to the primary 
dial-out number failed 
If the number is not busy, check the modem connected to 
the CONTROL DCE connector. If the called number is often 
busy, you may also increase the number of call retries 
MAJOR ON 
16 
DIAL-OUT ALTERNATE 
CALL FAILED 
The call attempts to the alternate 
dial-out number failed 
If the number is not busy, check the modem connected to 
the CONTROL DCE connector. If the called number is often 
busy, you may also increase the number of call retries  
MAJOR ON 
17 
SELF TEST ERROR 
A problem has been detected during 
FCD-E1LC self-test 
Replace the FCD-E1LC.  MAJOR  ON/OFF 
21 
SIGNAL LOSS 
Loss of main link port receive signal  1.  Check cable connections to the link connector. 
2.  Check line and/or other communication equipment 
providing the link to the remote unit. 
3.  Perform the power-up self-test and replace the 
FCD-E1LC if a failure is detected. 
MAJOR ON/OFF 
22 
EXCESSIVE BPV 
The rate of bipolar violations in the 
main link receive signal exceeds 
1 × 10
-6
 during a measurement interval 
of 1000 seconds 
1.  Problem in the network facilities used by the main link. 
2.  Turn the FCD-E1LC off for a few minutes, and then 
turn it back on and read the alarm messages generated 
during the power-up self-test. Replace the FCD-E1LC if 
a failure is detected 
MAJOR ON/OFF 