Specifications
FOM-40 Installation and Operation Manual  Appendix C IR-G.703/CO Interface Module 
  Selecting the IR-G.703/CO Timing  C-3 
INT/RCV Timing 
The INT/RCV clock is used in applications that recover the clock signal from the 
modem link. This mode is used when the attached equipment has a G.703 
codirectional interface but cannot produce clock signals. The module has an 8-bit 
FIFO buffer to compensate for the phase delay introduced by the G.703 device. 
Figure C-4 illustrates the buffer connection and the required application setup. 
If the FOM-40 modem is set to the internal or receive timing, configure the 
IR-G.703/CO module to the INT/RCV clock. 