Specifications
Quick Start Guide  Installation and Operation Manual 
2  Configuring RICi-E3, RICi-T3  RICi-E3, RICi-T3 Ver. 1.0 
2.  Configuring RICi-E3, RICi-T3 
Configure RICi-E3, RICi-T3 to the desired operation mode via an ASCII terminal 
connected to the rear panel CONTROL port. Alternatively, you can manage 
RICi-E3, RICi-T3 over Telnet, a PC running a Web browsing application, or SNMP via 
the Ethernet or E3 port. 
Remote management requires assigning an IP address. 
Starting a Terminal Session 
  To start a terminal session: 
1.  Connect an ASCII terminal to the CONTROL port at the front panel. The 
default settings are as follows: 
  Baud Rate: 115,200 bps 
  Data Bits: 8 
  Parity: None 
  Stop Bits: 1 
  Flow Control: None. 
2.  To optimize the view of the system menus, do the following: 
  Set the terminal emulator to VT100. 
  If you are using HyperTerminal, set the terminal mode to the 132-column 
mode. 
3.  Enter your user name and password and proceed with the management 
session. 
The RICi-E3, RICi-T3 default user name is su (lower case). The default password is 
1234. 
Note 
Note 