Specifications
Chapter 4 Configuration  Installation and Operation Manual 
4-10  Configuring for Management  RICi-E3, RICi-T3 Ver. 1.0 
  To modify the control port parameters: 
1.  Navigate to Main Menu > Configuration > System > Control Port. 
The Control Port menu appears as illustrated in 
Figure 4-8
. 
RICi-E3, RICi-T3 
Configuration>System>Control Port 
 Terminal Type    (VT100) 
2. Baud Rate      (115200 bps) 
3. Set Scrolling Window Size[0 - 11]    (4) 
3. Security Timeout (min)[0 - 60]    (10) 
> 
ESC-prev menu; !-main menu; &-exit     1 user(s) 
Figure 4-8. Control Port Menu 
2.  From the Control Port menu, select Baud Rate. 
3.  Type in the desired baud rate. Available baud rates are 9600, 19200, and 
115200 bps. 
4. Select Set Scrolling Window Size to set the size of the status information 
section at the bottom of the screen in the range of 0 to 11. 
5. Select Security Timeout to disable it (0) or set to in the range of 10 to 60 
seconds. 
6. Select Save. 