Specifications
Chapter 4 Configuration  Installation and Operation Manual 
4-12  Configuring for Operation  RICi-E3, RICi-T3 Ver. 1.0 
  To configure the Ethernet port: 
1.  From the Physical Ports menu, select Ethernet. 
The Ethernet menu appears as illustrated in 
Figure 4-9
. 
RICi-E3, RICi-T3 
Configuration > Physical Ports > Ethernet 
1. Administrative Status  (Up) 
2. Auto-Negotiation  (Enable) 
3. Flow Control  (Enable) 
4. Max Capability Advertised   (100base - TX Full Duplex) 
5. MDIX Auto cross over  (Enable) 
> 
ESC-prev menu; !-main menu; &-exit 1 user(s) 
Figure 4-9. Ethernet Menu 
2.  In the Ethernet menu, configure the following: 
  Administrative Status 
  Up – the network port is enabled 
  Down – the network port is disabled. 
  Autonegotiation 
  Enable – autonegotiation is enabled 
  Disable – autonegotiation is disabled 
  Flow Control 
  Enable – flow control is enabled 
  Disable – flow control is disabled. 
  Max Capability Advertised. The highest traffic handling capability to be 
advertised during the autonegotiation process 
  10baseT Half Duplex 
  10baseT Full Duplex 
  100baseTX Half Duplex 
  100baseTX Full Duplex. 
  MDIX Auto cross over 
  Enable – MDIX Auto cross over is enabled 
  Disable – MDIX Auto cross over is disabled. 
3. Select Save to complete the network Ethernet port configuration. 