Specifications
Chapter 4 Configuration  Installation and Operation Manual 
4-14  Configuring for Operation  RICi-E3, RICi-T3 Ver. 1.0 
Configuring the T3 Port 
RICi-T3 includes a T3 port. You can configure its parameters at the physical level 
as follows: 
  To configure the T3 port: 
1.  From the Physical Ports menu, select T3. 
The T3 menu appears as illustrated in 
Figure 4-11
. 
RICi-T3 
Configuration > Physical Ports >T3 
1. Administrative Status (Up) 
2. Framing (M23) 
3. Tx Clock (LBT) 
4. Line Build Out (Up to 225ft) 
5. Protocol (LAPS) 
ESC-prev menu; !-main menu; &-exit 1 user(s) 
Figure 4-11. T3 Menu 
2.  From the T3 menu, configure the following: 
  Administrative Status 
  Up – the network port is enabled 
  Down – the network port is disabled. 
  Framing. Specifies the framing type 
  M23 
  C-bit. 
  Tx Clock. Specifies the clock 
  Internal Clock 
  LBT. 
  Line Build Out for Line Mode = DSU. The length of a cable in feet between 
T3 port connector and the network access point 
  Up to 225 feet – 0 to 225 ft 
  Over 225 feet – 225 ft and further. 
  Protocol. Specifies the encapsulation 
  HDLC 
  LAPS. 
3. Select Save to complete the user T3 port configuration. 
The selected value shows in the T3 Port configuration menu. 