Specifications
Chapter 4 Configuration  Installation and Operation Manual 
4-20  Additional Tasks  RICi-E3, RICi-T3 Ver. 1.0 
  To access the Monitoring menu: 
•  From the Main menu, select Monitoring. 
The Monitoring menu appears as illustrated in 
Figure 4-18
. 
RICi-E3, RICi-T3 
Monitoring 
1. System  > 
2. Physical Ports  > 
3. Applications  > 
> 
ESC-prev menu; !-main menu; &-exit; 1 user(s) 
Figure 4-18. Monitoring Menu 
Displaying System Status Information 
System menu specifies MAC address of the RICi-E3, RICi-T3 unit and provides 
access to the information on the interface connection status. For description of 
RICi-E3, RICi-T3 system messages, which are displayed via the Log File screen, 
refer to 
Chapter 5
. 
  To display interface connection information: 
1.  Navigate to Main Menu > Monitoring > System > Connection Status. 
The Connection Status screen appears as illustrated in 
Figure 4-19 
for E3 
and 
Figure 4-20
 for T3 respectively. 
RICi-E3 
Monitoring>System>Connection Status 
 Index Description Type Status Operation Speed 
 1 ETHERNET PORT Fast Eth copper Up Up 100000000 
 2 E3 PORT DS3 Up Up 34368000 
r – Refresh Table 
ESC-prev menu; !-main menu; &-exit; ?-help 
Figure 4-19. E3 Connection Status Screen 
The Connection Status screen includes the following information: 
  Description – ETH (User) or E3/T3 (Network) interfaces 
  Type – type of the interface according to the INF TYPE MIB 
  Status – administrative status of the link (Up or Down), as set via the 
Ethernet as illustrated in 
Figure 4-9
, and E3/T3 a illustrated in 
Figure 4-10
and 
Figure 4-11 
respectively. 
  Operation –current operational status of the link (Up or Down). 