Specifications
Chapter 5 Configuring a Typical Application  Installation and Operation Manual 
5-2  Connecting the Cables  RICi-E3, RICi-T3 Ver. 1.0 
5.2  Connecting the Cables 
Connecting the Ethernet Port 
  To connect the Ethernet interface: 
•  Connect the user LAN to the RJ-45 connector designated 10/100 BaseT. 
Connecting the E3 or T3 Port 
  To connect the E3 or T3 interface: 
1.  Connect the Rx cable to the BNC designated Rx. 
2.  Connect the Tx cable to the BNC designated Tx 
Connecting the Power 
RICi-E3, RICi-T3 accept either 110-240 VAC or 48/60 VDC power through the 
same power inlet. 
Before connecting or disconnecting any cable, the protective earth terminals of 
this unit must be connected to the protective ground conductor of the mains (AC 
or DC) power cord. If you are using an extension cord (power cable) make sure it 
is grounded as well. 
Any interruption of the protective (grounding) conductor (inside or outside the 
instrument) or disconnecting of the protective earth terminal can make this unit 
dangerous. Intentional interruption is prohibited. 
Connecting AC Power 
AC power is supplied to the RICi-E3, RICi-T3 modem through a standard 3-prong 
connector. 
AC power should be supplied via a 1.5m (5 ft) standard power cable terminated 
by a standard 3-prong connector. A cable is provided with the unit. 
  To connect AC power: 
1.  Connect the power cable to the power connector on the RICi-E3, RICi-T3 rear 
panel. 
2.  Connect the power cable to the mains outlet. 
The unit will be turned on automatically upon connection to the mains. 
Warning 