Specifications
Installation and Operation Manual  Chapter 5 Configuring a Typical Application 
RICi-E3, RICi-T3 Ver. 1.0  Configuring the RICi-E3, RICi-T3 System Parameters  5-3 
Connecting DC Power 
A special IEC 60320 adapter for -48/-60 VDC power supply is available. 24 VDC 
RICi-E3, RICi-T3 units have a terminal block DC inlet and adapter supplied with the 
unit. 
  To connect DC power: 
Refer to the DC power supply connection supplement for instructions how to wire 
the DC adapters, and to the 
Handling Energized Products
 section. 
5.3  Configuring the RICi-E3, RICi-T3 System Parameters 
Make sure that the RICi-E3, RICi-T3 unit is properly installed and connected to an 
ASCII terminal. 
Configuring Parameters via ASCII Terminal 
  To configure the RICi-E3, RICi-T3 system parameters: 
1.  Configure an ASCII terminal as follows: 
  Baud rate: 115200 bps 
  one start bit, eight data bits, no parity, one stop bit, no flow control, and 
VT100 emulation. 
2.  Connect the terminal to the CONTROL port at the rear panel. 
3. Press <Enter> to initiate the control session and then enter the user name 
and password. The default user name and password for the superuser are as 
follows: 
  User Name: su (lower case) 
  Password: 1234 
4.  Configure the system parameters necessary: 
Main Menu > Configuration > System > Management > Host IP 
  Host IP Address: Define the host IP address 123.123.123.123 
  Host IP Mask: 255.255.255.0 
  Default Gateway: 123.123.321.321 