Installation and Operation Manual  Chapter 5 Configuring a Typical Application 
RICi-E3, RICi-T3 Ver. 1.0  Configuring the Physical Ports  5-5 
Configuring the Ethernet Port 
  To configure the Ethernet port parameters: 
1.  Navigate to the Ethernet menu: 
Main Menu > Configuration > Physical Ports > Ethernet 
2.  Configure the Ethernet parameters as specified below: 
  Administrative Status: Up 
  Autonegotiation: Enable 
  Flow Control: Enable 
  Max Capability Advertised: 100BaseTx. 
3. Select Save. 
Configuring the Bridge Parameters 
  To configure the bridge parameters: 
1.  Navigate to the Bridge menu: 
Main Menu > Configuration > Applications > Bridge 
2.  Configure the Bridge parameter values as specified below: 
  Forwarding Mode: Transparent 
  Aging Time: 300. 
3. Select Save. 
Building the MAC Table 
  To configure the static MAC table: 
1.  Navigate to the Static MAC Table menu: 
Main Menu > Configuration > Applications > Bridge > Static MAC table 
2. Press <A>to add a static MAC address. 
The Static MAC Table display changes, entering the Add mode. 
3.  In Add mode, perform the following: 
  Select MAC Address, and enter a new MAC address. 
  Select Receive Bridge Port, and choose a RICi-E3, RICi-T3 interface this 
MAC address will be attached to. 
  Select Save to save the MAC address. 
  Press <Esc> to return to the Static MAC Table. 