System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 2 Agent Configuration Mode 
Displaying All Active Alarms 
 
To display a list of all Megaplex active alarms: 
•  From the Fault menu, select Alarms followed by Display and All… or click 
the Alarms>Display button  . 
The Mux Active Alarm List appears. The order of alarms in the table can be 
sorted by clicking on the column headers with an asterix “*”. 
Figure 2-28. Mux All Active Alarm List 
Table 2-14. Mux All Active Alarm Parameters 
Parameter  Possible Values / Remarks 
No. Alarm No. 
Code  Code number of the alarm 
Slot  IO slot where alarm occurred 
Port  Port where alarm occured 
Description  Brief description of the alarm 
Severity  Indication of the effect level of the alarm: 
Event, Warning, Minor, Major, Critical 
State  Type of alarm: 
Off - No alarms or events in port 
Event - At least one alarm event (including state on, off events) since the last 
Alarms>Clear operation 
Major - At least one active major alarm since the last Alarms>Clear operation 
Minor - At least one active minor alarm since the last Alarms>Clear operation 
Megaplex Level Fault Operations  2-27 