System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 2 Agent Configuration Mode 
 
To display attributes of masked alarms (Mask = Yes or Yes and Save) within 
the selected level in the Alarm Attributes table: 
1. In the Attributes group, select Mask. 
If the selected level is All, all masked alarms appear in the Alarms 
Attributes table. 
If the selected level is System, only masked alarms whose Slot and Port are 
NA appear in the Alarms Attributes table. 
If the selected level is Card and ports, only masked alarms whose slot 
matches the Level group’s Slot parameter appear in the Alarms Attributes 
table. 
If the selected level is Ports, only masked alarms whose slot matches the 
Level group’s Slot and Port parameters appear in the Alarms Attributes 
table. 
2. Click <Apply>. 
 
To display attributes of inverted alarms (Invert = Yes) within the selected level 
in the Alarm Attributes table: 
1. In the Attributes group, select Invert. 
If the selected level is All, all inverted alarms appear in the Alarms 
Attributes table. 
If the selected level is System, only inverted alarms whose Slot and Port 
are NA appear in the Alarms Attributes table. 
If the selected level is Card and ports, only inverted alarms whose slot 
matches the Level group’s Slot parameter appear in the Alarms Attributes 
table. 
If the selected level is Ports, only inverted alarms whose slot matches the 
Level group’s Slot and Port parameters appear in the Alarms Attributes 
table. 
2. Click <Apply>. 
 
To display attributes of filtered alarms (Filter = Yes) within the selected level 
in the Alarm Attributes table: 
1. In the Attributes group, select Filter. 
If the selected level is All, all filtered alarms appear in the Alarms Attributes 
table. 
If the selected level is System, only filtered alarms whose Slot and Port are 
NA appear in the Alarms Attributes table. 
If the selected level is Card and ports, only filtered alarms whose slot 
matches the Level group’s Slot parameter appear in the Alarms Attributes 
table. 
If the selected level is Ports, only filtered alarms whose slot matches the 
Level group’s Slot and Port parameters appear in the Alarms Attributes 
table. 
Megaplex Level Fault Operations  2-35 