System information
Chapter 2 Agent Configuration Mode  RADview-PC/TDM Megaplex-2100/2104 User’s Manual 
2. Click <Apply>. 
Defining Scope of Alarm Reports 
Using the Reports command, you can define the scope, type and severity of alarm 
reports that you will receive at the network management station. 
 
To define an alarm report: 
1. In the Fault menu, click Alarms, followed by Configuration and Reports… 
The Alarm Report dialog box appears. 
2.  Set the desired severity level for each report: Event, Warning, Minor, Major, 
or Critical. 
3. Click <Set>. 
Figure 2-33. Alarm Report Dialog Box 
Table 2-18. Alarm Report Parameters 
Parameter  Possible Values / Remarks 
Trap  Define whether you want to receive traps for all alarms or for only those alarms of at 
least a certain severity. 
Alarm On Severity - Minimum level of severity required for sending a trap to the 
network management station. Trap severity must be equal or higher than buffer severity. 
Alarm Off Severity - Maximum level of severity allowed for a trap not to be sent to the 
network management station. 
2-36  Megaplex Level Fault Operations 










