System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 2 Agent Configuration Mode 
Parameter  Possible Values / Remarks 
Buffer  Define whether you want the alarm buffer to contain all alarms (including traps) or only 
those alarms of at least a certain severity. 
Alarm On Severity - Minimum level of severity required for sending an alarm to the 
alarm buffer 
Alarm Off Severity - Maximum level of severity allowed for an alarm not to be sent to 
the alarm buffer 
A masked alarm does not appear in the buffer and no traps are sent for it, even if its 
severity matches the Alarm On Severity specified here. 
R1/R2 Relay  Define whether you want to receive the beep sound of the R1/R2 Relay contact for all 
alarms or for only those alarms of at least a certain severity. 
Alarm On Severity - Minimum level of severity required for sending a beep sound to the 
network management station 
ALR Minor LED  Define the level of severity at which the MTCL2’s ALR Minor LED turns on. 
ALR Major LED  Define the level of severity at which the MTCL2’s ALR Major LED turns on. 
Read ACM Alarm Descriptions 
Using the Read ACM Alarm Description command, you can initiate an update of 
the ACM Alarm Descriptions. 
 
To update the ACM Alarm Descriptions: 
•  In the Fault menu, click Alarms, followed by Configuration and Read ACM 
Alarm Descriptions … 
The ACM Alarm Descriptions are updated and saved in the NMS database. 
Displaying the History Log 
The History Log lists all Megaplex, card and port alarms since the last time the log 
was cleared. 
Displaying All Buffer Alarms 
The History Log>All command displays the entire contents of the Megaplex’s 
alarm buffer. 
 
To display the contents of the Megaplex's alarm buffer: 
•  From the Fault menu, select History Log followed by All… 
The All Active Alarms dialog box appears. The Alarm Buffer List displays all 
recorded Megaplex, card and port alarms since the last time the log was 
cleared. If the list is long, you can click the scroll bar or scroll arrows to 
display more entries. 
Megaplex Level Fault Operations  2-37 