System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 2 Agent Configuration Mode 
Figure 2-52. Software Configuration – VC Cards 
Table 2-38. VC Cards Software Configuration Parameters 
Parameter  Possible Values / Remarks 
Connect  Indicates whether the port should be considered in any of the Megaplex algorithms. 
No, Yes. 
Interface  For E&M, MTVC-2, VC-16A cards: 
2WIRE, 4WIRE 
For others: 
2WIRE 
Note: Interface is the same for all card ports except for VC-8, VC-16 and VC-16A cards 
where it can be different for each port. 
Tx Level (dBm)  Transmit level in steps of 1 or 0.5 dBm 
–17...8 
Note: Tx Level value can be offset by a certain value if Offset 1 is selected in the System 
Information dialog box. 
Rx Level (dBm)  Receive level in steps of 1 or 0.5 dBm 
–23...2 
Note: The Rx Level value can be offset by a certain value if Offset 1 is selected in the 
System Information dialog box. 
Agent Port Level Operations  2-63 