System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 2 Agent Configuration Mode 
Table 2-42. Testing Parameters (Test per TS/Bit Tab) 
Parameter  Possible Values / Remarks 
Slot  Slot number of the selected card 
IO-1 to IO-12 
For MP-2104: IO-1 to IO-5 
Port Selected port 
external-1 to external-12, internal-1 to internal-12 
Card Type  Type of card assigned to the selected slot 
TS Test  None, (L) Local Loop, (R) Remote Loop, (LB) Local BERT, (RB) Remote BERT, 
(LT) Local Tone Injection, (RT) Remote Tone Injection, (S) Split 
Note: When Split is selected, the tests are per bit. Otherwise, the tests are per TS. 
Bit 1..8 
 
To activate a test: 
1. In the New section, select a test. 
2.  Select duration for the new test. 
3. Click <Set>. 
 
To stop a currently running test: 
•  Click <Stop Test>. 
The Megaplex stops running the current test. This command is not 
applicable for Ext Init Local Loop tests. 
 
To reset the BERT counter to zero (if a BERT test is currently running): 
•  Click <Clear Bert>. 
The BERT counter restarts at zero, even if the BERT test continues. 
BERT Counters 
 
To inject errors: 
1. In the Agent Card View, click a port. 
2. From the Diagnostics menu, select Bert Counters… 
The Bert Counters dialog box appears (Error! Reference source not 
found.). 
3. Click <Polling Interval>. 
The Polling Interval dialog box appears. Select the desired polling interval 
and click <Set>. 
4. Click <Start>. 
The Errors appear in the BERT Log. 
Port Level Diagnostic Tests  2-71 