System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 2 Agent Configuration Mode 
Figure 2-60. Current Data Dialog Box 
The Current Data dialog box shows the amount of time that error(s) exist(s) in the 
current measurement interval. Each interval is 15 minutes (900 seconds). 
Table 2-45. Current Data Parameters 
Parameter  Possible Values / Remarks 
Slot  Slot number of the selected card 
IO-1 – IO-12 
For MP-2104: IO-1 to IO-5 
Card Type  Type of card inserted into the selected slot 
MTML-2/T1(CSU), MTML-2/T1(DSU), MTML-2/E1(DSU), MTML-2/E1(LTU) 
Port Selected port 
external-1 
Time Elapsed  Number of seconds since the beginning of the current interval 
Errored Seconds  Number of seconds in the current interval in which an event or alarm occurred 
SESs  Severe Errored Seconds. Number of seconds in the current interval in which at least 
320 CRC events or one OOF event occurred 
UASs  Unavailable Seconds. Number of seconds in the current interval in which a failed signal 
state exists. A failed signal state occurs after 10 consecutive severe errored seconds. This 
state is cleared only after the Megaplex processes 10 consecutive seconds of data 
without an SES 
CSSs  Controlled Slip Seconds. Number of seconds in the current interval in which at least one 
controlled SLIP event occurred 
BESs  Bursty Errored Seconds. Number of seconds in the current interval in which 2 - 319 CRC 
events occurred 
Degraded 
Minutes 
Number of minutes in the current interval in which the bit error rate (BER) exceeded 
1x10
-6
Displaying Port Statistics  2-77 