System information
Chapter 1 Edit Configuration Mode  RADview-PC/TDM Megaplex-2100/2104 User’s Manual 
1-20  System Level Configuration Operations 
Net Update 
The Net Update command allows you to save the current Edit Configuration 
and/or flip configuration to all Megaplexes in the net. 
Figure 1-18. Net Update Submenu 
Saving the Configuration 
The Save Config command allows you to save the current Edit Configuration as 
the Megaplex's temporary configuration without activating it over the net. 
 
To save the current Edit Configuration as the Megaplex's temporary 
configuration: 
1. From the Configuration menu, select Net Update followed by Save Config... 
The Net Update Save Config dialog box appears. 
2.  Configure desired parameters and click <Apply>. 
If the sanity check is successful, the download proceeds and the selected 
Edit Configuration is saved as the temporary configuration of the Megaplex 
but not activated over the net. 
If warnings appear, completion of the download process requires user 
confirmation. If the sanity check detects errors, RADview aborts the 
download process and displays the error message, “Sanity Check errors 
encountered by NMS”. To view a list of detected errors, click 
<View Errors>. 
Figure 1-19. Net Update Save Config Dialog Box 
Table 1-9. Net Update Save Config Parameters 
Parameter  Possible Values / Remarks 
Configuration Id  Configuration ID number of Edit Configuration that you want to save as the temporary 
configuration. 
Description  Brief description of the selected Edit Configuration. 
 
To abort the Save Config operation in process: 
•  Click <Abort>. 










