System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 1 Edit Configuration Mode 
System Level Configuration Operations  1-25 
Click on the right mouse button to change the fields in the TS Data dialog box. 
Figure 1-25. R2 Data – TS Data Tab Dialog Box 
Table 1-11. R2 Data Parameters 
Parameter  Possible Values / Remarks 
Signaling Profile  The profile number selected in the Select Profile dialog box 
1 to 5 
General Tab 
R2 Mode  Auto: default value of timers will be used by R2, according to selected Country 
Manual: user can change the value of R2 timers within the valid limits, specific to 
each country 
Country 
ITU–T
, Korea, India, Brazil (continuous), Brazil (pulsed), Argentina, 7, 8, 9, 10 
R2 Delay  Eenables you to configure link as satellite or terrestrial. Seize acknowledge detect 
timing is much shorter for terrestrial link than for satellite link (1-2 sec) 
Terrestrial
, Satellite 
Metering Indication  Indicates which Bit will be used for Metering Indication 
C Bit
, B Bit 
Timers Tab 
The parameters of the Timers Tab are Read-Write only when R2 Mode = Manual 
Break-Make Ratio 
(msec) 
Break-Make Ratio of Pulse Duration  
56–44, 64–36
, 80–20 
Release Guard T2 
(msec) 
Release guard timing before going to idle 
16..2000 
Note 