System information
Chapter 1 Edit Configuration Mode  RADview-PC/TDM Megaplex-2100/2104 User’s Manual 
1-26  System Level Configuration Operations 
Parameter  Possible Values / Remarks 
Regret Duration (sec)  Regret duration 
14
..120 
Seize Detect (msec)  Minimum duration to detect a valid seizure 
24..448 
Seize Ack. Delay (msec)  Delay before sending a valid seize ack signal 
8
..304 
Clear-Back Detect 
(msec) 
Minimum duration to recognize a valid clear-back 
24
..448 
Clear-Forward Detect 
(msec) 
Minimum duration to recognize a valid clear-forward 
200..504 
Fault Detect (msec)  Minimum duration to recognize a block signal 
16..104 
Fault Removal Detect 
(msec) 
Minimum duration to recognize a valid block removal signal 
16..104 
Meter Pulse Duration 
(msec) 
Duration of metering pulse to be sent 
120..304 
Seize Ack. Wait (msec)  Minimum duration to receive seizure acknowledge signal 
104..1200 
Seize Ack. Detect 
(msec) 
Minimum duration to recognize a valid seizure acknowledge signal 
48
..600 
Answer Detect (msec)  Minimum duration to recognize a valid answer signal 
64..448 
Block Removal Detect 
(msec) 
Minimum duration to recognize a valid block removal signal 
16
..96 
Metering Pulse Detect 
(msec) 
Minimum duration of incoming meter pulse 
64..448 
Forced Disconnect 
Detect (msec) 
Minimum duration to recognize disconnect signal 
304..448 
Disconnect Ack. Detect 
(msec) 
Minimum duration to recognize disconnect acknowledge signal 
304..448 
Release Guard T1 
(msec) 
Minimum duration to release guard. During this time, no new call can be initiated 
16..2000 
TS Data Tab 
TS TS Index 
1..31 
Call Enable  Indicates the Enabled Call direction for the specific TS 
Both
, Incoming, Outgoing 
Metering  Indicates if the specific TS supports Metering 
Yes, No