System information
Chapter 1 Edit Configuration Mode  RADview-PC/TDM Megaplex-2100/2104 User’s Manual 
1-30  System Level Configuration Operations 
3. Click <Set> in the Variant Data dialog box (Figure 1-30). 
Figure 1-31. Change Variant TS Dialog Box – Gen. Tab 
Table 1-13. V5.1 Variants Parameters – Gen. Tab 
Parameter  Possible Values / Remarks 
TS Time Slot 
1..31 
TS Type  Time Slot Type 
NC, PSTN, ISDN B1, ISDN B2, C Channel, Permanent B1, Permanent B2, Semi-
Permanent B1, Semi-Permanent B2 
Port ID  IO Port ID this TS is connected to 
0..16777215 
EF/L3 Address  Address of the IO port this TS is connected to. IO port is identified according to its 
Address: 
for ISDN ports: EF Address. Valid values: 0..8175 
for PSTN ports: L3 Address. Valid values: 0..32767 
65535=notApplicable (FFFF). 
NA, 0..32768 
Slot  Slot containing the IO port this TS is connected to 
NA, IO-1..IO-12 
Port  IO Port this TS is connected to 
NA, external-1..external-16, internal-1.. internal-2 