System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 1 Edit Configuration Mode 
System Level Configuration Operations  1-33 
3.  To see more information about a selected variant, click <Var. Data> to 
display the Variant Data dialog box (Figure 1-30). 
4. Click <OK> to enter the data in the NMS database. 
Figure 1-34. Read V5.1 Variants 
Setting Redundancy Table Parameters 
The Redundancy Table command enables you to set redundancy parameters for 
the Megaplex. 
Only slots containing MTML and HSH cards are available for redundancy 
operations. MTML-H ports can be redundant only to MTML-H ports; HSH ports can 
be redundant only to HSH ports. 
 
To view or change redundancy table parameters: 
•  From the Configuration menu, select Redundancy Table…. 
The Redundancy Table dialog box appears. Fields in the table (marked 
with an asterisk *) can be reordered by clicking on their columns. 
Redundancy Mode will display the parameters in the following order: Y 
Cable, Dual Cable Parallel Tx. Additionally every group will be displayed 
according to Primary Slot and Port ascending order. 
Note 