Figure 1-35. Redundancy Table Dialog Box 
Table 1-15. Redundancy Table Parameters 
Parameter  Possible Values / Remarks 
Redundancy Mode  Redundancy Mode for the card 
Y Cable, Dual Cable Parallel Tx 
Primary Slot  Primary Slot for the card 
NA, IO-1..IO-12 
Primary Port  Primary Port for the card 
External-1..External-2, Internal-1, Bundle1..Bundle120 
Note: 
For ML-1/T1, ML-1/E1 cards: only external-1 is available 
For MLML-H, HSH cards: only external-1 is available 
Secondary Slot  Secondary Slot for the card 
NA, IO-1..IO-12 
Secondary Port  Secondary Port for the card 
External-1..External-2, Internal-1, , Bundle1..Bundle120 
Note: 
For ML-1/T1, ML-1/E1 cards: only external-1 is available 
For MLML-H, HSH cards: only external-1 is available 
Recovery Time (sec)  Recovery time in seconds 
1..99 
[Add…]  To open the Add Redundancy Couple dialog box, click <Add…>. Select the 
desired parameters and click <Set>. 
[Change…]  To open the Change Redundancy Couple dialog box, select a line in the table and 
click <Change…>. Select the desired parameters and click <Set>. 
[Remove]  To remove a Redundancy Couple, select a line in the table and click <Remove>. 