System information
Chapter 1 Edit Configuration Mode  RADview-PC/TDM Megaplex-2100/2104 User’s Manual 
1-56  Port Level Configuration Operations 
Table 1-29. SW Cfg>> Tab MTML2/E1 
Parameter  Possible Values / Remarks 
Connect  Indicates whether the port should be considered in any of the Megaplex algorithms 
No, Yes 
Line Type  The line type of the interface 
E1-MF (G.732S), E1 (G.732N), E1-CRC (G.732NCRC), E1-CRC-MF (G.732SCRC) 
Restore Time 
(sec) 
The time required to restore normal service after the end of a loss of synchronization 
condition: 
CCITT, 1, 10 
<<SW Cfg Tab 
Table 1-30. <<SW Cfg Tab MTML2/E1 
Parameter  Possible Values / Remarks 
Idle Code (hex)  Hexadecimal code transmitted to fill idle (unused) time slots in frames transmitted 
through the selected port: 
0 to FF 
The following values are not allowed: 0, 8, 10, 12, 21, 24, 42, 49, 84, 92 
Inband Mng  Identifier of inband management over the link 
Off, FDL or TS0, Dedicated TS, Dedicated TS/PPP, Dedicated FR 
Inband Mng Rate 
(Kbps) 
Data rate of the inband management. Options depend on Inband Mng 
8, 16, 32, 64 
Inband Mng Rout 
Protocol 
Protocol of Inband Mng 
For Inband Mng =Dedicated TS/PPP or Dedicated FR: 
None, RIP2, Proprietary 
ML Rdn Tab 
Table 1-31. ML Rdn. Tab MTML2/E1 
Parameter  Possible Values / Remarks 
Redundancy 
Mode 
ML redundancy mode 
Dual Cable Parallel Tx: ML card is connected by a separate cable to other Megaplexes 
Y Cable: Y Cable connects two MTML cards to two Megaplexes, through one cable (only 
applicable for same types CSU or DSU of MTML cards) 
Primary Port  Primary Port 
Secondary Slot  Secondary Slot 
Secondary Port  Secondary Port 