System information
Chapter 1 Edit Configuration Mode  RADview-PC/TDM Megaplex-2100/2104 User’s Manual 
1-62  Port Level Configuration Operations 
Parameter  Possible Values / Remarks 
OOS Signal  State of the signaling bits when the link is in out-of-service (OOS) state: 
Forced Idle – Signaling bits A and B are idle when the link is in out-of-service 
state. In addition, if the line type is ESF, signaling bits C and D are also idle. 
Forced Busy - Signaling bits A and B are busy when the link is in out-of-service 
state. In addition, if the line type is ESF, signaling bits C and D are also busy. 
Busy Idle - Signaling bits A and B are busy for 2.5 seconds, then become idle 
until the out-of-service state ends. In addition, if the line type is ESF, signaling bits 
C and D are idle for 2.5 seconds before switching to busy state. 
Idle Busy - Signaling bits A and B are idle for 2.5 seconds, then become busy 
until the out-of-service state ends. In addition, if the line type is ESF, signaling bits 
C and D are busy for 2.5 seconds before switching to idle state. 
Signaling Profile  1, 2, 3, 4, 5 
IP Address  IP Address 
IP Mask  IP Mask 
Echo Canceller 
Off
, On 
 
To display bundle parameters for an ML-IP internal port: 
1. In the Card View, click the required port. 
2. From the Configuration menu, select Bundles... 
The Bundles dialog box appears. 










