System information
RADview-PC/TDM Megaplex-2100/2104 User’s Manual  Chapter 1 Edit Configuration Mode 
Port Level Configuration Operations  1-67 
Parameter  Possible Values / Remarks 
Analog Signaling  For VC-6A cards: 
Loop–Start
For VC-6AG cards (same for all card ports): 
Loop–Start
For VC-8 (same for all card ports): 
Loop–Start,
 Wink Start 
VC-16 cards (same for every adjacent 8 ports): 
Loop–Start,
 Ground–Start, Wink Start  
Meter Rate  For VC-6A/FXO, VC-6A/FXS cards: 
When Signaling Profile=3, 3 Metering Pulse: 16
, 12 else NA 
For VC-8/FXO, VC-8/FXS, VC-16/FXO, VC-16/FXS cards: 
16
, 12 
Note: Meter Rate is the same for all card ports. Some versions of VC–8/FXO, VC–16/FXO 
cards do not support Meter Rate. An alarm is issued if 12 or 16 is selected. 
E&M Type  For VC-8/E&M, VC-16/E&M cards: 
Type 1, Type 2, Type 3, SSDC5
Note: E&M Type is the same for every 4 adjacent ports (1..4, 5..8, 9..12, 13..16). 
Signaling 
Feedback 
For VC-8/FXO, VC-16/FXO cards: 
No
, Yes 
Note: Signaling Feedback is the same for every 8 adjacent ports (1..8, 9..16). 
Remote Type  Only for VC-6A/4LB cards 
LB
, PBX 
Conversation 
Time (min) 
Only for VC-6A/4LB cards 
2
, 3, 5, Unlimited 
Link To Slot 
IO-1..IO-12, NA 
Note: Only slots containing ML cards are available for selection 
Link To Port  External-1..External-2, Internal-1, NA (when Link to Slot=NA) 
Port ID 
Port ID 
Note: Exists only for cards that support V5.1. Enabled only when Connect=V.5.1. 
VC-6 Destination Parameters 
Table 1-37. Destination Parameters – VC–6 
Parameter  Possible Values / Remarks 
Dest Connect 
No, Yes 
Dest Mux  Mux ID 
Enter an internal ID number for Mux, nor IP address or Mux name 
Dest Slot  Destination Slot 
Unknown, IO-1.. IO-15 
Dest Port  Destination Port 
Unknown, External-1.. External-12, Internal-1..Internal-12 