Specifications
Installation and Operation Manual  Chapter  1 Introduction 
Optimux-106 Ver. 6.1  Functional Description  1-7 
Management and Monitoring 
Optimux-106 units are equipped with a control port (CONTROL) and an Ethernet 
management port (MNG-ETH) located on the rear panel. The MNG-ETH port 
operates at a rate of 10/100 Mbps and can be set to 10/100 full- or half-duplex, 
with or without autonegotiation. It supports flow control and an MDI/MDIX 
connection. 
The management interface supports the following management methods: 
•  Supervision Terminal – An ASCII terminal connected to the control port (or a 
PC running a terminal emulation program) can be used as a supervision 
terminal. All software required for the various management functions 
available through the terminal is contained in the Optimux-106. 
•  SNMP Management – A built-in SNMP agent that enables SNMP management 
of the Optimux-106 via the MNG-ETH connector. The SNMP agent enables 
fully graphical, user-friendly management using RADview stations offered by 
RAD, as well as management by other SNMP-based systems. 
•  WEB Management – Optimux-106 has an option to be connected via 
management port (MNG-ETH connector) that is supported by TCP/IP protocol, 
and can be connected to the Ethernet network port 
•  Telnet Management – Optimux-106 has an additional option to be managed 
by Telnet. 
Physical Characteristics 
Optimux-106 is a compact unit, intended for installation on desktops or shelves. 
Unit height is 1U (1.75 inch). An optional rack-mount adapter kit enables 
installation of Optimux-106 in a 19-inch rack. 
Power Requirements 
Optimux-106 can be ordered with one or two AC/DC wide-range power supplies 
for operation on AC (100-240 VAC) or on DC (-40 to -72 VDC) sources. 
Each power supply (A and B) can be ordered as one of the above power supply 
types. 
When two power supplies are installed, they share the load. If one of the power 
supplies fails or its input power is disconnected, the other power supply 
continues providing power to Optimux-106. 










