Specifications
Chapter  4 Configuration  Installation and Operation Manual 
4-6  Configuring Optimux-106 for Operation Optimux-106 Ver. 6.1 
Configuring the Control Port 
The control port is used to connect a console terminal to the Optimux-106 
device. 
Configuration>System>Control Port
1. Baud rate > (115200 bps) 
2. Security Timeout > (10 min.) 
3. Pop Alarms > (On) 
> 
Please select item <1 to 3> 
ESC-Previous menu; !-Main Menu; &-Exit 
Figure 
4-8. Control Port Menu 
Table 
4-5. Control Port Parameters 
Parameter Possible Value (default 
value in bold) 
Description 
Baud rate  9600 bps 
19200 bps 
38400 bps 
57600 bps 
115200 bps 
The baud rate that matches your management 
terminal device. 
Security Timeout  Integer representing number 
of minutes 
Default: 10 min. 
A timeout value in minutes. This value is the number 
of minutes of management inactivity after which 
Optimux-106 automatically disconnects from the 
management session. To reconnect, press <Enter> on 
the management terminal and then log in again. 
Pop Alarms  On 
Off 
When POP Alarms is On, new alarms appear at the 
bottom of the terminal screen. Regardless of the POP 
Alarms setting, the alarms are written to the log file. 
4.2  Configuring Optimux-106 for Operation 
Configuring Ethernet Port Parameters 
Configuring the MNG-ETH port 
The MNG-ETH port opion is for the management and user Ethernet configuration 
of Optimux-106. 
³  To configure MNG-ETH port: 
1.  From the configuration menu select Physical Layer. 
The Physical Layer screen is displayed. 