Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-106 Ver. 6.1  Configuring Optimux-106 for Operation  4-7 
Optimux-106 
Configuration>Physical Layer 
 1. Ethernet > 
 2. Link > 
 3. T1 > 
> 
Please select item <1 to 3> 
ESC-prev. menu; !-main menu; &-exit 1 user(s) 
Figure 
4-9. Physical Layer Menu 
2.  From the Physical Layer menu select Ethernet. 
The Ethernet menu is displayed. 
The Ethernet menu may display the configuration for either ETH-MNG or ETH-USER 
depending on the Port Number selected. To toggle between configurations, select 
Port Number and the Port Number Menu appears (
Figure 
4-11
). 
Optimux-106 
Main Menu>Configuration>Physical Layer>Ethernet 
1. Device number > (Local) 
2. Port number > (MNG-ETH) 
3. Port name …() 
4. Auto Negotiation > (Enabled) 
5. Flow Control > (Enabled) 
6. Alarms > (Unmasked) 
> 
Please select item <1 to 6> 
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s) 
Figure 
4-10. Ethernet Menu 
Table 
4-6. Ethernet Management Parameters 
Parameter Possible Value 
(default value in 
bold) 
Description 
Device Number  Local 
Remote 
Identifies the device Location 
Port number  MNG-ETH 
USER-ETH 
Opens menu for the MNG-ETH port 
Opens menu for the USER-ETH port 
Port name  String up to 15 
characters 
A name easily Identifies the Ethernet port 
Auto Negotiation  Enabled 
Disabled 
Enables auto-negotiation. 
Flow Control  Enabled 
Disabled 
Enables flow control. 