Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-106 Ver. 6.1  Configuring Optimux-106 for Operation  4-9 
Table 
4-9
 describes the fields in the Ethernet management menu. 
Table 
4-7. Ethernet USER Parameters 
Parameter Possible Value  Description 
Device Number  Local 
Remote 
Identifies the device Location 
Port number  MNG-ETH 
USER-ETH 
Opens menu for the MNG-ETH port 
Opens menu for the USER-ETH port 
Port name  String up to 15 
characters 
A name easily Identifies the Ethernet port 
Administrative 
Status 
UP 
Down 
Port status is up. 
Port status is down. 
Autonegotiation  Enabled 
Disabled 
Enables autonegotiation. 
Flow Control  Enabled 
Disabled 
Enables flow control. 
Alarms Masked 
Unmasked 
Identifies whether alarms triggered by this 
Ethernet port are masked or not. When 
masked, these alarms are not trapped and 
are not recorded in the log file. 
3.  Select Administrative Status and set the status to either Up or Down. 
4.  Select Port Name to set a name to the port (ETH-USER only). 
5.  Select Autonegotiation and toggle between the Enabled or Disabled options. 
6.  Select Flow Control to toggle between the Enabled or Disabled options. 
7.  Select Alarms to mask or unmask the USER Ethernet alarms. 
Configuring Fault Propagation 
Optimux-106 has an option of Alarm Forwarding (Fault propagation) of the 
USER-ETH port. The user can enable or disable this option. 
The control port is used to connect a console terminal to Optimux-106. 
Configuration>System
1. Management > 
2. Control Port > 
3. Fault Propagation (Off) 
4. Alarms > 
5. Redundancy > 
6. Factory Default > 
Please select item <1 to 3> 
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s) 
Figure 
4-13. Control Port Menu 










