Specifications
Chapter  4 Configuration  Installation and Operation Manual 
4-10  Configuring Optimux-106 for Operation Optimux-106 Ver. 6.1 
Table 
4-8. Ethernet USER Fault Propagation 
Parameter Possible Value 
(default value in 
bold) 
Description 
Fault Propagation  On 
Off 
Activate Fault Propagation functionality: 
•  When signal loss or sync loss is 
detected on the uplink, the USER 
Ethernet port on both (local and 
remote products) is shut down. 
•  When the USER Ethernet port detects 
that the link is down, it automaticaly 
shuts down the USER ethernet port on 
the remote product. 
Deactivate the Fault propagation 
functionality 
Configuring T1 Channel Parameters 
The following menu is used to configure the T1 ports. 
Optimux-106 
Main Menu>Configuration>Physical Layer>T1 
1. Device Number > (Local) 
2. Port number > (1) 
3. Port Name ... () 
4. Line Code > (B8ZS) 
5. Line Length (ft) > (0-133) 
6. Alarms > (Unmasked) 
> 
Please select item <1 to 6> 
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s) 
Figure 
4-14. T1 Configuration Screen 
Table 
4-9. T1 Channel Parameters 
Parameter Possible Value  Description 
Device Number  Local 
Remote 
Identifies whether parameters shown are 
for the local or remote device. 
Port number  1 to 4  Identifies the T1 port to configure. 
Port Name  String of up to 15 
characters 
Default: 
A name to easily identify this T1 port. 
Line code  B8ZS 
AMI 
Identifies the T1 Line coding 