Specifications
Optimux-106 Ver. 6.1  Monitoring Performance  5-1 
Chapter  5 
Monitoring and 
Diagnostics 
5.1  Monitoring Performance 
You can monitor the following aspects of the Optimux-106 system: 
•  System up-time 
•  MAC Address 
•  Alarms and events 
•  Interface status 
•  Local system status 
•  Remote system status. 
Optimux-106 
Monitoring>System 
 MAC Address ... (00-20-D2-22-E1-5F) 
 Sys Up Time ... (05:06:34) 
1. Active Alarms [1] > 
2. Event Log [5] > 
3. Status > 
4. Interface Status [] > 
5. Clear Log File 
> 
Please select item <1 to 5> 
ESC-Previous menu; !-Main Menu; &-Exit        1 User(s) 
Figure 
5-1. Monitoring Menu 
Table 
5-1. System Monitoring Parameters 
Parameter Description 
MAC Address  The address the device holds when transmitting frames 
via the Ethernet port. 
Sys Up Time  Elapsed time since system was powered up. 
Active Alarms  Displays the number of active alarms. 
To view the alarms, enter 1. 