Specifications
Chapter  5 Monitoring and Diagnostics  Installation and Operation Manual 
5-6  Monitoring Performance  Optimux-106 Ver. 6.1 
Monitoring the Status of the Uplink 
Monitoring>Physical Layer>Link 
1. Device Number > (Local) 
2. Port Number > (LINK A) 
 Operation > (Up) 
 Alarm Indication > (Normal) 
 Test Indication > (Off) 
 Alarm > (Unmasked) 
> 
Please select item <1 to 1> 
ESC-Previous menu; !-Main Menu; &-Exit        1 User(s) 
Figure 
5-6. Uplink Status Screen 
Table 
5-5. Uplink Status Parameters 
Parameter Possible Values Description 
Device Number  Local 
Remote 
Identifies the device currently 
being monitored. 
Port Number  LINK A or LINK B  Identifies the uplink currently 
being monitored. 
Operation  Up 
Down 
Indicates the current 
operational status of the 
device. 
Alarm Indication  Normal 
Signal loss 
Indicates the highest status 
level of current alarms. 
Test Indication  On 
Off 
Indicates whether a loopback 
test is currently being run. 
Alarm Masked 
Unmasked 
Identifies whether alarms on 
the device are masked or not. 
When masked, Ethernet alarms 
are not trapped. 
³  To monitor the status of the uplink: 
1.  To toggle between the local and remote device, enter 1. 
The Device Number changes to identify the unit currently being 
monitored. 
2.  To toggle between LINK A and LINK B, enter 2. 
The screen displays the current status of the selected port on the 
selected device. 